ProTek® Hurricane Mitigation Products Overview
Storefront & Entrance Systems
The YKK AP ProTek Non-Shuttered Systems comply with Impact & Cycle Testing Requirements for Large and Small Missiles and meet or exceed the Air, Water, and Structural Requirements.
YHS 50 Framing System
- Design Pressure up to +70/-90 psf
- Glazing: 9/16” Monolithic
YHS 50 FI Framing System
- Design Pressure up to +/-70 psf
- Glazing: 1-5/16” Insulating
YHS 50 TU Framing System
- Thermally-Broken using YKK AP
- Thermabond Plus® Technology
- Design Pressure up to +/-70 psf
- Spans up to 9’-0” tall
- Glazing: 1-5/16” Insulating
35H Entrance Doors
- Singles: 4’-0” x 8’-0”, Pairs: 8’-0” x 8’-0”
- Transom Frames up to 10’-0”
- Maximum Security Locking System (Five Point for Pairs and Three Point for Single Doors) or Optional Exit Devices
Operable Windows and Sliding Doors
YKK AP offers three operable impact resistant windows and two sliding doors
for Non-Shuttered Applications. Each product has been thoroughly tested for both Large and Small Missile Impact Resistance.
YOW 225 H Non-Thermal Operable & Fixed Windows
- Glazing: 9/16” Monolithic
- Large and Small Missile up to +/-65 psf for Operable,
- +70/-90 psf for Fixed
YOW 225 TUH Thermally Broken Operable & Fixed Windows
- Glazing: 1-3/16” Insulating
- Large and Small Missile up to +/- 65 psf
YVS 410 TUH Thermally Broken Single Hung & Fixed Windows
- Glazing: 1-1/16” Insulating
- Large and Small Missile up to +80/- 120 psf
YSD 700 H Non-Thermal Sliding Glass Doors
- Glazing: 9/16” Monolithic
- Large and Small Missile, 5’-0” x 8’-0” Panels up to +100/-120 psf
- Glazing: 1-3/16” Insulating
- Large and Small Missile, 4’-0” x 10’-0”
- Panels up to +100/-120 psf
YSD 600 TH Thermal Sliding Glass Doors
- Glazing: 1-3/16” Insulating
- Large and Small Missile, 4’-0” x 8’-0” Panels up to +/-120 psf
Curtain Wall Systems
YKK AP offers three complete YKK AP ProTek curtain wall systems for Non-Shuttered Applications. All three systems have been thoroughly tested and approved for both Large and Small Missile Impact Resistance.
YHC 300 OG Outside Glazed
- Single & Multiple Spans Design Pressures up to +/-90 psf
- Linear Spacing of Verticals up to 5’-0” CL to CL
- Glazing: 9/16” Monolithic & 1-5/16” Insulating
YHC 300 SSG Structural Silicone @ Intermediate Verticals
- Single & Multiple Spans Design Pressures up to +/-90 psf
- Linear Spacing of Verticals up to 4’-0” CL to CL
- Glazing: 9/16” Monolithic & 1-5/16” Insulating
YHC 300 IG Inside Glazed
- Single & Multiple Span Design Pressures up to +/-130 psf
for Monolithic, +/-120 psf for Insulated* - Linear Spacing of Verticals up to 5’-0” CL to CL
- Glazing: 9/16” Monolithic & 1-5/16” Insulating
System & Glass Type | Frame Width | Frame Depth | Air Infiltration (CFM/SQ. FT.) | Water Infiltration (PSF) | Miami-Dade County Product Approval | General Florida Approval | Fla. Approved Dry Glazed Dupont® SentryGlas PlusTM | |
---|---|---|---|---|---|---|---|---|
YHS 50 | 2-1/2” | 5” | 0.015 | 10.3 | Yes | Yes | Yes | |
YHS 50FI | 2-1/2” | 5” | 0.020 | 12.0 | Yes | Yes | Yes | |
YHS 50TU | 2-1/2” | 5” | 0.020 | 12.0 | Yes | Yes | Yes | |
35H | 3-1/2” | Maximum Door SizeSingle: 4’-0” x 8’-0”Pair: 8’-0” x 8’-0” | 0.070 | 10.3 | Yes | Yes | Yes | |
YHC 300OG | 3” | 6-15/16” & 7-12” | 0.003 | 20.0 | Yes | Yes | Pending | |
YHC 300SSG | 3” | 6-15/16” & 7-12” | 0.001 | 20.0 | Yes | Yes | Pending | |
YHC 300IG | 3” | 6-15/16” & 7-12” | 0.010 (90PSF)0.040 (130PSF) | 20.0 | Yes | Yes | Pending | |
YOW 225H |
2-1/4” | Project Out 5’-0” x 3’-0”Casement 3’-0” x 5’-0”Fixed 4’-0” x 7’-0” | 0.040 (Operable)0.010 (Fixed) | 13.0 (Operable)15.0 (Fixed) | Yes | Yes | No | |
YOW 225TUH | 2-1/4” | Project Out 5’-0” x 3’-0”Casement 3’-0” x 5’-0”Fixed 4’-0” x 7’-0” | 0.030 | 15 | Yes | Yes | No | |
YVS 410TUH | 4” | Single Hung 3’-6” x 6’-0”Fixed 4’-0” x 8’-0” | 0.030 | 13 | Yes | Yes | No | |
YSD600TH | 6” | Panels to4’-0”x8’-0” | 0.020 | 20 | Yes | Yes | No | |
YSD700H | 7” | Panels to4’-0”x8’-0” | 0.105 | 20 | Yes | Yes | No |